Diabetes Technology & Therapeutics · 2015 · 48 citations · 35 references
MedicineInternal MedicineCritical Care PharmacotherapyDiabetologyMetabolic RegulationBlood Glucose MonitoringContinuous Glucose MonitoringDiabetes MellitusGlycemic ControlGlycemic MonitoringHypoglycemia ManagementBlood Glucose RegulationContinuous Glucose Monitoring Guided TherapyGlucose MonitoringGlucose Variability AssessmentGlycemic ExcursionsInpatient Glycemic ControlIntravenous Insulin InfusionIntravenous Insulin Therapy
BACKGROUND AND OBJECTIVE: Hyperglycemia occurs commonly in patients admitted to medical intensive care units (MICUs). Whether real-time (RT) continuous glucose monitoring (CGM) improves glycemic control and variability and reduces hypoglycemia in severely ill MICU patients with an Acute Physiology and Chronic Health Evaluation II (APACHE-II) score of ≥20 has not been studied. SUBJECTS AND METHODS: Thirty-five patients (66 ± 10 years of age; APACHE-II score, 28 ± 6) were randomly assigned to RT-CGM (n = 16) using the GlucoDay(®)S (A. Menarini Diagnostics, Florence, Italy) device or to blinded CGM. Insulin was infused using a modified Yale protocol targeting a blood glucose level between 80 and 120 mg/dL. Outcome measures were percentage of time in normoglycemia (80-110 mg/dL) and in hypoglycemia (<60 mg/dL), glycemic variability (SD, coefficient of variation, mean amplitude of glucose excursions, and mean of daily differences), and CGM accuracy (error grid analyses, Bland-Altman bias plot, and mean absolute relative deviation). RESULTS: During 96 h of monitoring, glycemia reached target (80-110 mg/dL) in 37 ± 15%, was between 70 and 180 mg/dL in 91 ± 10%, and <60 mg/dL in 2 ± 2% of the time. In the RT-CGM group glycemia averaged 119 ± 17 mg/dL versus 122 ± 11 mg/dL in the control group. Parameters of glucose variability and percentages of time at target glycemia and in hypoglycemia were similar between groups. GlucoDayS values and arterial glycemia correlated well, with 98.6% of data falling in Zones A and B of the error grid analysis. Mean absolute relative devation was 11.2%. CONCLUSIONS: RT-CGM did not ameliorate glucose control or variability; neither did it reduce the number of hypoglycemic events, but our insulin infusion protocol led to overall good glucose control without a significant hypoglycemia risk, making further improvement difficult.
35
William A. Knaus, Elizabeth A. Draper, Douglas P. Wagner et al. · Critical Care Medicine · 1985 · 13.7K citations
Medicine, Internal Medicine, Clinical Classification Systems +16
Intensive Insulin Therapy in Critically Ill Patients
Greet Van den Berghe, Pieter Wouters, Frank Weekers et al. · New England Journal of Medicine · 2001 · 10K citations · Full text
Intensive Insulin Therapy in the Medical ICU
Greet Van den Berghe, Alexander Wilmer, Greet Hermans et al. · New England Journal of Medicine · 2006 · 3.7K citations · Full text