PubMed · 1964 · 10 citations · 0 references
Life SciencesImmunologyMicrobiologyBacteriologyMedical MicrobiologyVirologyMedical BacteriologyPhage GeneticsBacteriophagesNeutralizationNeutralization MechanismsNeutralization ReactionsPhage CharacterizationPhage IsolationUltracentrifugation
Summary Three lots of bacteriophage ΦX174 were prepared by different techniques. Lot I was concentrated by dialysis against Carbowax 4000. Further concentration and purification were performed by differential centrifugation. Lot II was purified and concentrated by (NH 4 ) 2 SO 4 precipitation, followed by differential centrifugation. Lot III phage was treated exactly as the lot II phage except that it was further purified by RbC1 equilibrium density gradient ultracentrifugation. Analytical ultracentrifugation studies revealed that the lot II phage was composed of 114 S and 76 S particles and that the lot III phage contained only 113 S virions. The antibody levels of sera from rabbits injected with lot I ΦX174 showed a typical primary response. The levels increase more rapidly and to a greater extent following the second injection of phage. Serum obtained from one rabbit on the 6th day after the second injection of phage was designated S24 and was used for all subsequent neutralization studies. Serum from rabbits injected with filtrate material from a broth culture of the host organism, Escherichia coli strain C, failed to neutralize phage. In neutralization reactions with S24 diluted 2.8 × 10 4 times and lot I ΦX174 at an initial phage concentration ( P 0 ) of between 10 8 and 10 5 plaque-formers ml -1 , the over-all rate of change of the survivor fractions was not constant for every P 0 /serum concentration ratio. This fact could not be attributed to reversible neutralization nor to the strain of host bacterium used for assay of surviving phage. With P 0 between 6 × 10 8 and 6 × 10 5 plaqueformers ml -1 , neutralization of lot I ΦX174 by S24 diluted 6 × 10 4 times obeyed the percentage law, but the neutralization curves were not exponential. When the highly purified lot III ΦX174 was used in neutralization experiments with S24 diluted 6 × 10 4 times, the percentage law was obeyed when P 0 was between 4.08 × 10 8 and 4.08 × 10 5 plaque-formers ml -1 . In addition, all of the neutralization curves were exponential. The specific rate constant of the ΦX174-S24 system was dependent on the temperature of incubation. The Arrhenius constant was approximately 9600 calories mole -1 , corresponding to a Q 10 of about 1.8.