PubMed · 1976 · 15 citations · 16 references
MedicineCardiologyPhysiologyPulmonary Function TestingPulmonologyVentilationMitral StenosisPulmonary PhysiologyInspiratory Capacity AssessmentPulmonary Blood Flow MeasurementPulmonary HemodynamicsRegional Lung Function AssessmentRegional Lung VentilationVentilation Distribution
Relative regional ventilation and perfusion were measured with xenon-133 in 16 seated patients with pure or predominant mitral stenosis (group 1) and in 12 patients with chronic pulmonary congestion due to left-sided heart disease without mitral stenosis (group 2). The apex-base perfusion gradient was abnormally reduced and often reversed in group 1 patients. There was a significant negative correlation between perfusion gradient and mean pulmonary capillary pressure in both groups, but for a given elevation of pulmonary capillary pressure the perfusion gradient tended to be greater (i.e., less abnormal) in group 2. The regression line of perfusion gradient on pulmonary capillary pressure indicated that perfusion gradient had a value of zero (indicating reversal of the perfusion gradient) at a mean pulmonary capillary pressure of 26 mm Hg in group 2 but at only 18 mm Hg in group 1. Relative lower zone ventilation was abnormally reduced in group 1 and there was a significant negative correlation between ventilation gradient and pulmonary capillary pressure in group 1 but not group 2 patients. Comparison of the distribution of slowly inhaled small volume boluses, large volume boluses, and inspiratory capacity breaths of 133Xe suggested that the lower zone hypoventilation was due mainly to closure of peripheral airways but that selectively increased resistance and reduced compliance in the lower zones may contribute in some patients. Both ventilation and perfusion were reduced at the lung bases in group 1 patients, and between regions nonuniformity of relative ventilation/perfusion was significantly less than normal. Although ventilation distribution was relatively normal in group 2 patients, they also had significantly less regional ventilation/perfusion nonuniformity than normal subjects.
16
Distribution-Free Statistical Tests
C. B. Bell · Technometrics · 1970 · 1.7K citations
REGIONAL PULMONARY FUNCTION STUDIED WITH XENON133*
Wilmot C. Ball, P. Brian Stewart, L. G. S. Newsham et al. · Journal of Clinical Investigation · 1962 · 402 citations · Full text
Distribution of pulmonary perfusion in erect man.
Nicholas R. Anthonisen, J. Milic‐Emili · Journal of Applied Physiology · 1966 · 150 citations
Medicine, Anatomy, Pulmonology +10
Effect of inspiratory flow rate on regional distribution of inspired gas.
Björn Bake, L.W. Wood, Brian G. Murphy et al. · Journal of Applied Physiology · 1974 · 120 citations