PubMed · 2012 · 10 citations · 4 references
Veterinary MedicineOphthalmologyVeterinary OphthalmologyAnesthesiaClinical OptometryNeuro-optometryAnesthesia For Nonhuman PrimatesIntraocular Pressure MeasurementBiomedical ApplicationsIntraocular Pressure AssessmentIntraocular Pressure Management
AIM: To train Tibetan monkey (Macaca thibetana) for intraocular pressure (IOP) measurement in conscious state and obtain normal IOP in conscious Tibetan Macaque. METHODS: The training was based on award-conditioned behavior. Food stimulation and human-animal interaction were used in this training. RESULTS: Trained Tibetan monkeys calmly accepted IOP measurement by the TonoVet® rebound tonometer without sedation or anesthesia and their IOP values were similar to other primates. CONCLUSION: Human-cultivated Thibetan monkeys are tamable, and can be used for biomedical research such as ophthalmic research without anesthesia.
4
Evaluation of monkey intraocular pressure by rebound tonometer.
Wenhan Yu, Guiqun Cao, Xuyang Liu et al. · PubMed · 2009 · 27 citations
Medicine, Ophthalmology, Optometry +13