Vacuum heating hydrogen determination in aluminium and aluminium alloys

J Konar, Nilotpal Banerjee

1974 · 13 citations · 0 references

Concepts

Abstract

Estimation of hydrogen in aluminium and aluminium alloys by hot vacuum extraction method has been carried out at different temperatures starting from 600°C to 1200°C. The authors have established that 900°C is the optimum temperatures for the complete extraction of hydrogen. Below that temperature complete extraction could not be achieved. Shri J. Konar and Shri N.G. Banerjee, Scientists, National Metallurgical Laboratory)