Publication | Closed Access
Effect of PEEP on regional ventilation during laparoscopic surgery monitored by electrical impedance tomography
83
Citations
22
References
2011
Year
The effect of anesthesia, pneumoperitoneum, and different PEEP levels can be evaluated by EIT-based COV monitoring. An initial recruitment maneuver and a PEEP of 10 cmH(2)O preserved homogeneous regional ventilation during laparoscopic surgery in most, but not all, patients and improved oxygenation and respiratory compliance.