PubMed · 1983 · 96 citations · 0 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryOrthopedicsPhysical TherapyRehabilitationEnergy ExpenditureEnergy RequirementsHip BiomechanicsHip RehabilitationLower Extremity RehabilitationLower Limb RehabilitationEnergetic Cost ReductionEnergy Cost Of LocomotionEnergy Cost Of MovementEnergy Expenditure AlterationEnergy Expenditure AnalysisEnergy Expenditure In MovementSkeletal Disarticulation
Energy expenditure was measured using a metabolic measurement cart (MMC) for 8 patients with hip disarticulation (HD, group 1), 10 patients with hemipelvectomy (hp, group 2), and 11 able-bodied subjects (group 3). Velocity and O2 consumption of comfortable, fast, and slow walking speeds were measured with a MMC. Comfortable walking speeds with HD and hp were 51% to 61% of controls (p less than 0.001), but there was no difference in O2 uptake per minute among the three groups. Fast walking speeds for groups 1 and 2 was 70% to 75% of comfortable walking speeds in group 3 (p less than 0.01), and the mean O2 uptake of fast walking speeds in groups 1 and 2 was 40% to 50% more than that of group 3 at comfortable speeds. Energy cost per unit distance (work) was 80% to 125% greater with patient groups than with able-bodied subjects. The difference between the pre- and immediate postexercise pulse rates for comfortable walking speeds were higher in groups 1 and 2 than in group 3.