Publication | Open Access
THERMAL PERFORMANCE COMPARISON OF GLASS MICROSPHERE AND PERLITE INSULATION SYSTEMS FOR LIQUID HYDROGEN STORAGE TANKS
26
Citations
7
References
2008
Year
EngineeringLiquid Metal CoolingEnergy EfficiencyMechanical EngineeringExperimental ThermodynamicsThermal Energy StorageLiquid NitrogenGlass MicrospheresThermodynamicsMaterials ScienceElectrical EngineeringLarge Storage TanksEnergy StorageHydrogenHeat TransferPhase-change MaterialGas StorageThermal ManagementThermal EngineeringThermal InsulationElectrical Insulation
A technology demonstration test project was conducted by the Cryogenics Test Laboratory at the Kennedy Space Center (KSC) to provide comparative thermal performance data for glass microspheres, referred to as bubbles, and perlite insulation for liquid hydrogen tank applications. Two identical 1/15th scale versions of the 3,200,000 liter spherical liquid hydrogen tanks at Launch Complex 39 at KSC were custom designed and built to serve as test articles for this test project. Evaporative (boil-off) calorimeter test protocols, including liquid nitrogen and liquid hydrogen, were established to provide tank test conditions characteristic of the large storage tanks that support the Space Shuttle launch operations. This paper provides comparative thermal performance test results for bubbles and perlite for a wide range of conditions. Thermal performance as a function of cryogenic commodity (nitrogen and hydrogen), vacuum pressure, insulation fill level, tank liquid level, and thermal cycles will be presented.
| Year | Citations | |
|---|---|---|
Page 1
Page 1