Field Application of Performance Enhancing Chemicals to Metallized Zinc Anodes

Jack Bennett, James B. Bushman, Jorge Costa, Paul Noyce

2000 · 10 citations · 3 references

Concepts

Abstract

Abstract Performance enhancing chemicals were applied to metallized zinc anodes on three reinforced concrete field structures: a parking garage, a condominium, and a motorway substructure crosshead. In the parking garage, a structure that contained prestressed, post-tensioned reinforcing steel, 4-hr potential decays averaging 146 mV were measured on tendon anchorages. On the motorway crosshead, polarization was satisfactory 6 months after energizing, but decreased after 9 months operation in galvanic mode. Use of the enhancing agent at the condominium resulted in significant improvement in both protective current and steel polarization.

References

3