Heat Transfer Characteristics of Regenerator Matrix : Case of Packed Wire Gauzes

Kazuhiro HAMAGUCHI, Shintaro TAKAHASHI, Hideya MIYABE

TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B · 1983 · 20 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

The average heat transfer coefficient in the matrix of laminated wire screens (10 to 250 mesh) for a Stirling engine heat exchanger was studied experimentally. The data are correlated by N sub ud = 0.42 R sub ed 0.56 (3 or = R sub ed or = 400), and R sub ed are the Nusselt and Reynolds nubmers based on the wire diameter. The pressure drop decreased and the heat transfer increased as the wire diameter was decreased.