Thermal spray · 2002 · 17 citations · 2 references
Natural SciencesPhysicsAerodynamicsComputational Fluid DynamicsPlasma PhysicsPlasma DiagnosticsPlasma SimulationShock WavesEnthalpyJet PhysicsOblique Shock WavesPlasma ExpansionPlasma Jet FormationShock Formation In PlasmasShock Layer StructureShock Wave Dynamics
Abstract A numerical model of an argon jet exiting a LPPS torch has been developed and validated against enthalpy probe measurements for a slightly overexpanded jet at a chamber pressure of 100 mbar. Visualization of the jet using a CCD camera shows the presence of a small Mach reflection in the first compression-expansion cell with only oblique shock waves in the second cell. This jet topology is also observed in the model results. The images of the enthalpy probe on the axis of the plasma jet reveal that the shock layer, or shock-probe distance, varies according to the axial location of the probe. Shock-probe distance can be as large as 3 mm and should be considered when mapping plasma jets. Paper includes a German-language abstract.
2
Enthalpy probe performance in compressible thermal plasma jets
J.R. Fincke, W.D. Swank, S. C. Snyder et al. · Review of Scientific Instruments · 1993 · 32 citations