Catheterization and Cardiovascular Interventions · 2013 · 40 citations · 20 references
MedicineCardiologyRadiologyRadiation DosimetryRadiation ProtectionRadiation SafetyCoronary AngiographyPatient Radiation ProtectionPatient Radiation SafetyRadiation HealthRadiation Risk AssessmentRadiation TherapyFluoroscopy Time AnalysisIonizing Radiation Exposure AssessmentMedical Radiation Exposure MonitoringRadiation Dose AssessmentRadiation Effects On The Cardiovascular SystemRadiation Exposure ManagementX-ray Exposure AssessmentX-ray Imaging Parameters
OBJECTIVES: To evaluate practices for the protection from radiation of patients during coronary angiography (CA) and percutaneous coronary intervention (PCI), and to update reference values for the main radiation dose parameters. BACKGROUND: Few multicenter data from large populations exist on radiation doses to patients during CA and PCI. METHODS: RAY'ACT is a multicenter, nationwide French survey, with retrospective analysis of radiation parameters routinely registered in professional software from 33,937 CAs and 27,826 PCIs performed at 44 centers from January 1, through December 31, 2010. RESULTS: Kerma-area product (KAP) was registered in 91.7% (44/48) of centers and in 91.5% of procedures for CA (median, 27.2 Gy·cm(2) , interquartile range [IQR], 15.5-45.2) and 91.1% for PCI (median, 56.8 Gy·cm(2) , IQR, 32.8-94.6). Fluoroscopy time was registered in 87.5% (42/48) of centers and in 83.1% of procedures (median, 3.7 min, IQR, 2.3-6.3 for CA; 10.3 min, 6.7-16.2 for PCI). Variability across centers was high. Old equipment and routine left ventriculography were more common and number of registered frames and frame rate were higher in centers delivering high doses. The radial route was associated with lower doses than the femoral route (median KAP 26.8 Gy·cm(2) [15.1-44.25] vs. 28.1 [16.4-46.9] for CA, respectively; and 55.6 Gy·cm(2) [32.2-92.1] vs. 59.4 [24.6-99.9] for PCI, respectively; P < 0.01). CONCLUSIONS: This survey showed a very high rate of compliance with dose registration during CA and PCI in French nonacademic hospitals. Updated diagnostic reference values are established for the main dose parameters (KAP, 45 Gy·cm(2) for CA, 95 Gy·cm(2) for PCI).
20
Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures
Reza Fazel, Harlan M. Krumholz, Yongfei Wang et al. · New England Journal of Medicine · 2009 · 1.3K citations · Full text
Radiation Protection in Medicine
Annals of the ICRP · 2007 · 625 citations
Guidelines for Patient Radiation Dose Management
Stephen Balter, Richard B. Towbin, Donald L. Miller et al. · Journal of Vascular and Interventional Radiology · 2009 · 441 citations
John W. Hirshfeld, Stephen Balter, Jeffrey Brinker et al. · Circulation · 2005 · 436 citations