American Water Works Association · 1984 · 58 citations · 4 references
EngineeringChemical EngineeringEnvironmental EngineeringWastewater TreatmentWater Quality EngineeringWater TreatmentHeavy Metal RemediationHeavy Metal RemovalIndustrial Wastewater TreatmentNutrient RemovalWastewater ManagementWater PollutionIron RemovalManganese RemovalMetal RemovalPilot Study DesignWastewater Treatment For Heavy Metals
Processes in which oxidation is followed by removal of suspended solids can effectively remove soluble iron and manganese from water. Three common processes for removing iron and manganese are: (1) aeration‐filtration, (2) chlorination‐filtration, and (3) potassium permanganate‐manganese greensand filtration. This article describes these processes and presents results from a pilot study of chlorination‐filtration. The costs for oxidants in chlorination‐filtration are less than those for potassium permanganate‐manganese greensand filtration.
4