Adiabatic Capillary Tube Test Data for HFC-134a

H. Wijaya

Purdue e-Pubs (Purdue University System) · 1992 · 40 citations · 1 references

Full text

Open access

Concepts

Abstract

The function of a capillary tube, one of the most commonly used expansion devices, is to provide a restriction between the high and low side pressures of a refrigeration system.In so doing, it meters refrigerant at the desired flow rate for a given operating condition.At present, no experimental data are available for describing the performance of a capillary tube employing HFC-134a as a working fluid.The purpose of this study is to present experimental test data of adiabatic capillary tube performance for HFC-134a.A set of capillary tubes 5 feet to 10 feet long with inside diameters of 0.026, 0.031 and 0.033 inches was tested.The tests were conducted over a range of condensing temperatures and degrees of subcooling.A modified PAG oil (BRL 150, Allied-Signal Inc.U.S. Patent 4975212) with a viscosity of 150 sus was used.An oil separator which can be bypassed was installed to determine the effects of oil circulation on the capillary tube performance.Nomenclature A tube cross sectional area M refrigerant mass flow rate D inside tube diameter 4 P pressure difference f relative surface roughness Re Reynolds number f friction factor

References

1