PubMed · 2008 · 13 citations · 6 references
MedicineCardiologySurgeryCardiac TransplantationCardiothoracic SurgeryVascular SurgeryCardiopulmonary BypassCoronary Artery SurgeryHeart Transplant Candidate SelectionHeart TransplantationHemodynamic SupportMechanical Circulatory SupportAdult Heart TransplantationBridging CriteriaBridging Mechanical Circulatory SupportChronic Aortic DissectionIndications For Heart TransplantationLeft Main Coronary Artery DiseaseVentricular Assist Device Support
Herein, we report a successful bridge to heart transplantation by use of the TandemHeart percutaneous ventricular assist device (pVAD) in a chronic aortic dissection patient who was experiencing postcardiotomy shock. The patient had undergone an aortocoronary bypass to treat an acute, extensive myocardial infarction that had resulted from severe stenosis of a Cabrol-like graft to the left main coronary artery. The TandemHeart was used successfully, despite classic contraindications for pVAD support. The outcome shows that, in critically ill cardiogenic shock patients, a permissive approach to pVAD use is valuable in screening candidates for long-term ventricular assist device support or for heart transplantation. This case also reveals the validity of direct bridging to transplantation from a pVAD in carefully selected patients.
6
Clinical experience with the TandemHeart percutaneous ventricular assist device.
Biswajit Kar, Lindsay E Adkins, Andrew B. Civitello et al. · PubMed · 2006 · 136 citations
Medicine, Cardiology, Surgery +15
Pascal Vranckx, David P. Foley, Pim J. de Feijter et al. · International Journal of Cardiovascular Interventions · 2003 · 85 citations
Medicine, Cardiology, Surgery +13
Temporary assist device for postcardiotomy cardiac failure
Antoniοs Pitsis, Petros Dardas, Nikolaos Mezilis et al. · The Annals of Thoracic Surgery · 2004 · 31 citations