University of North Texas Digital Library (University of North Texas) · 1994 · 23 citations · 0 references
Open access
EngineeringChemical EngineeringCombustionRenewable Energy IntegrationRenewable Energy SystemsCogeneration SystemsEnergy ConversionSulfur CycleSulfur CyclingCombined Cycle IntegrationCombined Cycle Power PlantsGasificationPower GenerationSulfur Oxide RemovalSulfur RemovalSulfur-bearing SpeciesSulfuric Acid Formation
Tampa Electric Company (TEC) is in the construction phase for the new Polk Power Station, Unit {number_sign}1. This will be the first unit at a new site and will use Integrated Gasification Combined Cycle (IGCC) technology for power generation. The unit will utilize oxygen-blown entrained-flow coal gasification, along with combined cycle technology, to provide nominal net 26OMW of generation. As part of the environmental features of this process, the sulfur species in the coal will be recovered as a commercial grade sulfuric acid by-product. The sulfur will be removed from the synthesis gas utilizing a cold gas clean-up system (CGCU).