Journal of Applied Clinical Medical Physics · 2014 · 81 citations · 11 references
MedicineRadiologyRadiation DosimetryRadiation MeasurementRadiation ProtectionAbsorbed DoseExternal Beam DosimetryFilm DosimetryPhantom DosimetryRadiation Dose MeasurementRadiation TherapyCalibration Of Energy ResponseClinical Beam CalibrationMedical Dosimetry ApplicationsOptical Density CalibrationOptical Density MeasurementRadiation Dose AssessmentRadiation Quality DependenceX-ray Dosimetry
The objective of this study is to evaluate the suitability of recently introduced radiochromic film EBT3 for clinical dosimetry in the kilovoltage (kV) range. For this purpose, a kV X-ray irradiator, X RAD 320ix in the range 70 to 300 kVp, a clinical 60Co source, a 6 MV and an 18 MV X-ray clinical beam from a Varian linear accelerator were calibrated following AAPM dosimetry protocols. EBT3 films from two different EBT3 batches were placed side-by-side on the surface of a water phantom; doses from 0.5 to 4 Gy were delivered. Similarly, irradiations were performed for 60Co and 6 and 18 MV beams in a water equivalent phantom. Films were reproducibly placed at the center of a flatbed scanner and 48-bit RGB scans were obtained both pre- and postirradiations. Net optical density (netOD) and response for a given radiation quality relative to 60Co was determined for each EBT3 film. The netOD of the red color showed reproducible response (within 1%) for both batches when irradiated using the 60Co source. For a given dose of 1 Gy of kVp X-ray, the response relative to 60Co using the three color channels (red, green, and blue) decreases with decrease in kVp, reaching a maximum underresponse of ~ 20% for the 70 kVp. A significant underresponse of ~ 5% was observed at 300kVp. Responses of MV X-ray beams with respect to 60Co at the 1 Gy dose level showed no statistically significant difference. A relatively small difference in the response was observed between the two EBT3 batches used in this study in the kV X-ray range.
11
AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiology
Chao Ma, C Coffey, L DeWerd et al. · Medical Physics · 2001 · 819 citations · Full text
Precise radiochromic film dosimetry using a flat-bed document scanner
Slobodan Dević, Jan Seuntjens, E Sham et al. · Medical Physics · 2005 · 569 citations
Multichannel film dosimetry with nonuniformity correction
A Micke, David F. Lewis, Yu Xiang · Medical Physics · 2011 · 455 citations
Medicine, Radiology, Digital Imaging +15