MedicineCardiologyRadiologyDiagnostic ImagingDiagnostic RadiologyElectrophysiologyElectrophysiological MappingFluoroscopy-guided ProceduresIntracardiac ElectrophysiologyMedical Imaging InstrumentationMedical InstrumentationPoint-of-care Diagnostic DevicesAccuracy AssessmentAnatomical MapsCatheter GuidanceGuidance SystemsPre-registration ProcessesRegistrationSpatial Accuracy AssessmentThree-dimensional Electroanatomic Mapping
BACKGROUND: With increasing complexity in electrophysiology (EP) procedures, the use of electroanatomic mapping systems (EAMS) as a supplement to fluoroscopy has become common practice. This is the first study that evaluates spatial and point localization accuracy for 2 current EAMS, CARTO3(®) (Biosense Webster, Diamond Bar, CA, USA) and EnSite Velocity(®) (St. Jude Medical Inc., St. Paul, MN, USA), and for a novel overlay guidance (OG) software (Siemens AG, Forchheim, Germany) in a phantom experiment. METHODS AND RESULTS: A C-arm CT scan was performed on an acrylic phantom containing holes and location markers. Spatial accuracy was assessed for each system using distance measurements involving known markers inside the phantom and properly placed catheters. Anatomical maps of the phantom were acquired by each EAMS, whereas the 3D-based OG software superimposed an overlay image of the phantom, segmented from the C-arm CT data set, onto biplane fluoroscopy. Registration processes and landmark measurements quantitatively assessed the spatial accuracy of each technology with respect to the ground truth phantom. Point localization performance was 0.49 ± 0.25 mm in OG, 0.46 ± 0.17 mm in CARTO3(®) and 0.79 ± 0.83 mm in EnSite(®) . The registration offset between virtual visualization and reality was 1.10 ± 0.52 mm in OG, 1.62 ± 0.77 mm in CARTO3(®) and 2.02 ± 1.21 mm in EnSite(®) . The offset to phantom C-arm CT landmark measurements was 0.30 ± 0.26 mm in OG, 0.24 ± 0.21 mm in CARTO3(®) and 1.32 ± 0.98 mm in EnSite(®) . CONCLUSIONS: Each of the evaluated EP guidance systems showed a high level of accuracy; the observed offsets between the virtual 3D visualization and the real phantom were below a clinically relevant threshold of 3 mm.
14
Catheter ablation of atrial fibrillation without the use of fluoroscopy
Vivek Y. Reddy, Gustavo Morales, Humera Ahmed et al. · Heart Rhythm · 2010 · 184 citations
Medicine, Cardiology, Surgery +14
Heidi Estner, Isabel Deisenhofer, Armin Luik et al. · EP Europace · 2006 · 144 citations · Full text
Medicine, Cardiology, Surgery +16
Towards cardiac C-arm computed tomography
Guenter Lauritsch, Jan Boese, Lars Wigström et al. · IEEE Transactions on Medical Imaging · 2006 · 110 citations
Medicine, Cardiology, Radiology +16
S. Knecht, Hicham Skali, Mark O’Neill et al. · EP Europace · 2008 · 88 citations · Full text
Medicine, Cardiology, Radiology +15