Natural SciencesPhysicsSurgeryMedical PhysicsUltrasonographyUltrasoundDiagnostic UltrasonographyMusculoskeletal UltrasonographyUltrasonicsUltrasound InstrumentationUltrasound PhysicsBioeffects Of UltrasoundBurst DurationContinuous Mode OperationHeat Load DistributionTemperature Rise AnalysisTemperature Rise TestingTherapeutic Ultrasound TransducersUltrasound Therapy
OBJECTIVE: To compare tissue temperature rise and decay after 20-minute diathermy and ultrasound treatments. DESIGN AND SETTING: We inserted 3 26-gauge thermistor microprobes into the medial aspect of the anesthetized triceps surae muscle at a depth of 3 cm and spaced 5 cm apart. Eight subjects received the diathermy treatment first, followed by the ultrasound treatment. This sequence was reversed for the remaining 8 subjects. The diathermy was applied at a frequency of 27.12 MHz at the following settings: 800 bursts per second, 400-microsecond burst duration, 850-microsecond interburst interval, peak root mean square amplitude of 150 W per burst, and an average root mean square output of 48 W per burst. The ultrasound was delivered at a frequency of 1 MHz and an intensity of 1.5 W/cm(2) in the continuous mode for 20 minutes over an area of 40 times the effective radiating area. The study was performed in a ventilated research laboratory. SUBJECTS: Sixteen (11 men, 5 women) healthy subjects (mean age = 23.56 +/- 4.73 years) volunteered to participate in this study. MEASUREMENTS: We recorded baseline, final, and decay temperatures for each of the 3 sites. RESULTS: The average temperature increases over baseline temperature after pulsed short-wave diathermy were 3.02 degrees C +/- 1.02 degrees C in site 1, 4.58 degrees C +/- 0.87 degrees C in site 2, and 3.28 degrees C +/- 1.64 degrees C in site 3. The average temperature increases over baseline temperature after ultrasound were only 0.17 degrees C +/- 0.40 degrees C, 0.09 degrees C +/- 0.56 degrees C, and -0.43 degrees C +/- 0.41 degrees C in sites 1, 2, and 3, respectively. The temperature dropped only 1 degrees C in 7.65 +/- 4.96 minutes after pulsed short-wave diathermy. CONCLUSIONS: We conclude that pulsed short-wave diathermy was more effective than 1-MHz ultrasound in heating a large muscle mass and resulted in the muscles' retaining heat longer.
13
Temperature changes in human patellar tendon in response to therapeutic ultrasound.
Andrew K. Chan, J. William Myrer, Gary J. Measom et al. · PubMed · 1998 · 101 citations
The Stretching Window Part Two: Rate of Thermal Decay in Deep Muscle Following 1-MHz Ultrasound.
S C Rose, David O. Draper, Shane S. Schulthies et al. · PubMed · 1996 · 60 citations
Medicine, Physiology, Surgery +16