Journal of Applied Clinical Medical Physics · 2012 · 55 citations · 18 references
MedicineOncologyRadiation OncologyClinical Radiation OncologyRadiation DosimetryTreatment PlanningDose PrescriptionExternal Beam RadiotherapyRadiation Dose FractionationRadiation TherapyRadiation Treatment PlanningStereotactic RadiotherapyDose Fractionation RegimensRadiation Fractionation SchemesRadiotherapy Plan EvaluationStereotactic Body Radiotherapy DosimetryTreatment Planning DosimetryVolumetric Modulated Arc Therapy Dose PrescriptionVolumetric Modulated Arc Therapy DosimetryVolumetric Modulated Arc Therapy Planning
The purpose of this study was to demonstrate the dosimetric potential of volumetric-modulated arc therapy (VMAT) for the treatment of patients with medically inoperable stage I/II non-small cell lung cancer (NSCLC) with stereotactic body radiation therapy (SBRT). Fourteen patients treated with 3D CRT with varying tumor locations, tumor sizes, and dose fractionation schemes were chosen for study. The prescription doses were 48 Gy in 4 fractions, 52.5 Gy in 5 fractions, 57.5 Gy in 5 fractions, and 60 Gy in 3 fractions for 2, 5, 1, and 6 patients, respectively. VMAT treatment plans with a mix of two to three full and partial noncoplanar arcs with 5°-25° separations were retrospectively generated using Eclipse version 10.0. The 3D CRT and VMAT plans were then evaluated by comparing their target dose, critical structure dose, high dose spillage, and low dose spillage as defined according to RTOG 0813 and RTOG 0236 protocols. In the most dosimetrically improved case, VMAT was able to decrease the dose from 17.35 Gy to 1.54 Gy to the heart. The D(2cm) decreased in 11 of 14 cases when using VMAT. The three that worsened were still within the acceptance criteria. Of the 14 3D CRT plans, seven had a D(2cm) minor deviation, while only one of the 14 VMAT plans had a D(2cm) minor deviation. The R(50%) improved in 13 of the 14 VMAT cases. The one case that worsened was still within the acceptance criteria of the RTOG protocol. Of the 14 3D CRT plans, seven had an R(50%) deviation. Only one of the 14 VMAT plans had an R(50%) deviation, but it was still improved compared to the 3D CRT plan. In this cohort of patients, no evident dosimetric compromises resulted from planning SBRT treatments with VMAT relative to the 3D CRT treatment plans actually used in their treatment.
18
Stereotactic Body Radiation Therapy for Inoperable Early Stage Lung Cancer
Robert Timmerman · JAMA · 2010 · 2.5K citations · Full text
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Paul Keall, G Mageras, James M. Balter et al. · Medical Physics · 2006 · 2.3K citations · Full text
Stereotactic body radiation therapy: The report of AAPM Task Group 101
Stanley Benedict, Kamil M. Yenice, D Followill et al. · Medical Physics · 2010 · 2.2K citations · Full text
Volumetric modulated arc therapy: IMRT in a single gantry arc
Karl F. Otto · Medical Physics · 2007 · 1.9K citations · Full text
Medicine, Radiation Oncology, Clinical Radiation Oncology +16