OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1992 · 19 citations · 0 references
EngineeringNuclear EngineeringHeat TransferReactor PhysicsThermal AnalysisHeat Transfer In ReactorsReactor DesignReactor DynamicsReactor KineticsTemperature Control In ReactorsThermal-hydraulic Safety AnalysisCladding Temperature TransientsCoolant Flow DynamicsPower OscillationsPreheatingReactor StabilityReactor Stability AnalysisReactor Temperature StabilityReactor Transients
High feedwater flow and low temperature destabilize the reactor, whereas low feedwater flow restabilizes it by promoting steam condensation and feedwater preheating that reduce core inlet subcooling. Thermohydraulic oscillations arise when core coolant flow drops (both recirculation pumps tripped), causing sharp axial or radial fission power peaks and partial loss of feedwater preheating while high feedwater flow is maintained to preserve coolant inventory. Simulations on the BNL Engineering Plant Analyzer of over ninety BWR transients revealed power peaks up to seventeen times rated, transient flow reversals, fuel temperatures 1,030–2,090 K, cladding 560–570 K, and rapid suppression‑pool temperature excursions, while BOP system feedback strongly affected stability; the EPA proved effective for scoping calculations and accident‑management support.
March 9, 1989 instability at the LaSalle-2 Power Plant and more than ninety related BWR transients have been simulated on the BNL Engineering Plant Analyzer (EPA). Power peaks were found to be potentially seventeen times greater than the rated power, flow reversal occurs momentarily during large power oscillations, the fuel centerline temperature oscillates between 1,030 and 2,090 K, while the cladding temperature oscillates between 560 and 570 K. The Suppression Pool reaches its specified temperature limit either never or in as little as 4.3 minutes, depending on operator actions and transient scenario. Thermohydraulic oscillations occur at low core coolant flow (both Recirculation Pumps tripped), with sharp axial or redial fission power peaking and with partial loss of feedwater preheating while the feedwater is flow kept high to maintain coolant inventory in the vessel. Effects from BOP system were shown to influence reactor stability strongly through dosed-loop resonance feedback. High feedwater flow and low temperature destabilize the reactor. Low feedwater flow restabilizes the reactor, because of steam condensation and feedwater preheating in the downcomer, which reduces effectively the destabilizing core inlet subcooling. The EPA has been found to be capable of analyzing BWR stability `` shown to be effective for scopingmore » calculations and for supporting accident management.« less