Release of Iodine and Noble Gas Fission Products from Defected Fuel Elements during Reactor Shutdown and Start-Up

Brent J. Lewis, R.D. MacDonald, Hugues W. Bonin

Nuclear Technology · 1990 · 19 citations · 8 references

Concepts

Abstract

AbstractData from a single defected fuel element operating in-reactor are used to develop a physically based model for describing the increased release of iodine and noble gas fission products to the primary coolant following a reactor shutdown and start-up. Iodines are only released on reactor shutdown, whereas both species are observed on start-up. A dependence on the decay constant of λ-3/2 is typically observed for these transient releases, indicative of a source of release from fuel cracking with little holdup due to transport in the fuel-to-sheath gap.