Nuclear Science and Engineering · 1977 · 10 citations · 0 references
Natural SciencesPhysicsNuclear PhysicsRadiation DetectionRadiation MeasurementActivation AnalysisNeutron Activation AnalysisNeutron DetectionNeutron ScatteringNuclear Cross SectionsActivationElastic Neutron ScatteringElastic ScatteringNeutron AttenuationNeutron Attenuation CoefficientsNuclear Elastic ScatteringSingle ScatteringSurface Barrier Detectors
The cross section of the 58Ni(n, p)58Co reaction was determined by the activation method for neutron energies from 3 to 4.8 MeV. Neutron fluxes were measured with a laboratory-fabricated proton recoil telescope consisting of a radiator, an evacuated cell, and a surface barrier detector. The absolute efficiencies of the telescope for different neutron energies have been interpreted by Monte Carlo calculation as well as by a direct integration method. The fraction of activations induced by neutrons following single elastic scattering to those without scattering in the nickel sample was also calculated by a Monte Carlo program. The neutron attenuation through the nickel sample was also considered. Major sources of error in the cross-section determination are summarized and discussed. The total error was estimated to be 4 to 5%.