Anaesthesia · 2010 · 24 citations · 17 references
Manikin StudySpeech PerceptionPhonatory AerodynamicsMedicineSimulated Difficult IntubationOtorhinolaryngologyAintree Intubating CatheterLarynxSuccessful IntubationSurgeryAirway ManagementVoice SurgeryAnesthesiaVoice EvaluationFibreoptic IntubationFibreoptic‐guided IntubationAnesthesiologyHealth Sciences
In this randomised crossover manikin study of simulated difficult intubation, 26 anaesthetists attempted to intubate the trachea using two fibreoptic-guided techniques: via a classic laryngeal mask airway using an Aintree intubating catheter and via an intubating laryngeal mask airway using its tracheal tube. Successful intubation was the primary endpoint, which was completed successfully in all 26 cases using the former technique, and in 5 of 26 cases using the latter (p < 0.0001). The former technique also proved quicker to reach the vocal cords with the fibrescope (median (IQR [range])) time 18 (14-20 [8-44]) s vs 110 (70-114 [30-118]) s, respectively; p = 0.008); and to first ventilation (93 (74-109 [52-135]) s vs 135 (79-158 [70-160]) s, respectively; p = 0.0038)]. We conclude that in simulated difficult intubation, fibreoptic intubation appears easier to achieve using a classic laryngeal mask airway and an Aintree intubating catheter than through an intubating laryngeal mask airway.
17
Use of the Intubating LMA-Fastrach™ in 254 Patients with Difficult-to-manage Airways
David Ferson, William H. Rosenblatt, Mary Johansen et al. · Anesthesiology · 2001 · 307 citations · Full text