Journal of Medical Imaging and Radiation Oncology · 2012 · 12 citations · 18 references
MedicineOrthopaedic SurgerySurgeryBone MetabolismInterventional RadiologyOrthopedicsAblation TherapyBone TumorsBiopsy Needle PlacementBone Lesion AssessmentBone Tumor AblationBone Tumor BiopsyNeedle Biopsy TechniqueOsteoid Osteoma ImagingRadiofrequency TreatmentTissue Impedance Monitoring
INTRODUCTION: The aim of this study is to assess the safety and the efficacy of radiofrequency ablation (RFA) of osteoid osteoma with Soloist monopolar electrode using tissue impedance, rather than temperature, as an indicator of osteonecrosis. METHODS: The medical records and imaging studies of 30 patients (males 18, females 12) who underwent RFA of osteoid osteoma at our institution were reviewed. The mean age of the patients was 15.3 years (range 5-34 years) and the mean duration of follow up was 26.9 months (range 3-52 months). The lesions were located in the femur (n=6, 53%), tibia (n = 8, 27%), hand (n = 3, 10%), foot (n = 2, 6%) and humerus (n = 1, 3%). The procedure was performed with general anaesthesia under CT guidance. The nidus was accessed with 11-gauge bone biopsy needle and then the stylet was removed and replaced by monopolar 16.5G radiofrequency probe with a 9-mm active tip through the coaxial axis. Power delivery via the radiofrequency generator was started at 2 W and increased gradually until the end point of 450-500 Ω reached and 'Roll-Off' achieved indicating coagulation necrosis of the target lesion. RESULTS: The procedure was technically successful in all patients. The mean procedure time was 72 min and the mean RFA time was 12.7 min. The clinical success rate was 93%. In one patient, the procedure was abandoned due to immature Roll-Off despite all measures. In one patient (3%), recurrence occurred 39 months after the procedure. No major complications were encountered. Two minor skin burns occurred that were resolved with conservative measures. CONCLUSION: RFA of osteoid osteoma using Soloist monopolar electrode is a safe and effective treatment. Tissue impedance could be used as an alternative to temperature to indicate osteonecrosis of osteoid osteoma during RFA.
18
Ablation of osteoid osteomas with a percutaneously placed electrode: a new procedure.
Daniel I. Rosenthal, Alice Alexander, Andrew E. Rosenberg et al. · Radiology · 1992 · 426 citations
Medicine, Neurosurgery, Surgery +12
Percutaneous radiofrequency ablation in osteoid osteoma
Norbert Lindner, Toshifumi Ozaki, Robert Roedl et al. · Journal of Bone and Joint Surgery - British Volume · 2001 · 267 citations · Full text
Osteoid Osteoma: Clinical Results with Thermocoagulation
Geert Vanderschueren, A. H. M. Taminiau, Wim R. Obermann et al. · Radiology · 2002 · 205 citations
Osteoid Osteoma: CT-guided Percutaneous Resection and Follow-up in 38 Patients
N. Sans, D. Galy-Fourcade, J Assoun et al. · Radiology · 1999 · 182 citations