NASA STI Repository (National Aeronautics and Space Administration) · 1951 · 16 citations · 0 references
Open access
EngineeringAerospace EngineeringMechanical EngineeringAerodynamicsAerospace StructuresTunnel EngineeringAerodynamic TestingAirfoil TheoryExperimental AerodynamicsSubsonic AerodynamicsSupersonic AerodynamicsWind-tunnel TestingAngle Of AttackAngle Of Attack EffectsAngle Of Attack MeasurementMach NumberSupersonic Wind TunnelsTotal PressureWind Tunnel Pressure Testing
A wind-tunnel investigation has been conducted.to determine the effect of inclination of the air stream on the measured pressures of 20 total-pressure tubes through an angle of attack of -15 0 to 45 0 at Mach numbers 1.62, 1.94, and 2.40.Results obtained with these same tubes at subsonic speeds have been previously reported in NACA RM L50G19.The results of the investigation have indicated that~ in general, the range of angle of attack over which the tubes remained insensitive to inclination was appreciably greater at supersonic speeds than at subsonic speeds.The increase in range of insensitivity for most of the cylindrical tubes was from about 4 0 to 6 0 ; whereas the increase for conical-and ogival-nose sections 'was from about 4 0 to 10 0 The only tube which showed a decrease in performance at supersonic speeds was a shielded total-pressure tube (Kiel type), which was insensitive (to within 1 percent of the impact pressure) over an angle-of-attack range -of 41.5 0 at pubsonic speeds but only 37 0 at a Mach number of 1.94 .. The range of insensitivity of this tube, however, was still the greatest of any of the tubes tested, both at subsonic and at supersonic speeds.The present tests also' showed that the effect of the various design variables was the same at supersonic speeds as at subsonic speeds.The performance of cylindrical tubes, for example, was superior to that of tubes having conical-and ogival-nose shapes.Sharp leading edges and impact openings which were ~arge with ,respect to the diameter of the tube were also shown to increase the perfo~nce of thetube.Conical chambers were shown to have better misalinement characteristics than pylindrical chambers, and chambers having a 15 0 bevel angle 'were f'oUndto be superior to larger internal bevels.A leadin:g.;.edge profile -having a slant angle of 10 0 was found to have a beneficial effect in shifting the calibrations of a cylindrical tube with.'ala:rgeimpact ''Openihg-so' that -the tube .remained insensitive to higher positive angles of attack.