Publication | Closed Access
Neutron Capture and Transmission Measurements and Resonance Parameter Analysis of Niobium
30
Citations
16
References
2006
Year
EngineeringNuclear PhysicsPhysicsRadiation DetectionNatural SciencesNuclear DataResonance Parameter AnalysisNeutron CaptureNeutron SourceGlass Scintillation DetectorInstrumentationTransmission MeasurementsMetallic Nb SamplesNeutron ScatteringNuclear Engineering
Epithermal neutron capture and transmission measurements were performed using the time-of-flight method at the Rensselaer Polytechnic Institute linac using metallic Nb samples. The capture measurements were made at the 25-m flight station with a 16-section sodium iodide multiplicity detector and the transmission measurements at the 25-m flight station with a 6Li glass scintillation detector. Resonance parameters were determined for all resonances up to 500 eV with a combined analysis of capture and transmission data using the multilevel R-matrix Bayesian code SAMMY. The results are compared to those presented in ENDF/B-VI, updated through Release 3.
| Year | Citations | |
|---|---|---|