Academic Emergency Medicine · 2010 · 93 citations · 31 references
MedicineEmergency MedicineRadiologyDiagnostic ImagingPediatric Emergency MedicineUltrasonographyClavicle FracturesEmergency UltrasoundPediatric Emergency ImagingPediatric OrthopedicsPediatric UltrasonographyPediatric UltrasoundEmergency Medicine UltrasonographyEmergency Pediatric UltrasoundOutcome MeasuresPediatric Clavicle FracturesPediatric Fracture DetectionProximal Clavicle FracturesRadiography In Pediatric EmergenciesShoulder Radiography
OBJECTIVES: Clavicle fractures are among the most common orthopedic injuries in children. Diagnosis typically involves radiographs, which expose children to radiation and may consume significant time and resources. Our objective was to determine if bedside emergency department (ED) ultrasound (US) is an accurate alternative to radiography. METHODS: This was a prospective study of bedside US for diagnosing clavicle fractures. A convenience sample of children ages 1-18 years with shoulder injuries requiring radiographs was enrolled. Bedside US imaging and an unblinded interpretation were completed by a pediatric emergency physician (EP) prior to radiographs. A second interpreter, a pediatric EP attending physician with extensive US experience, determined a final interpretation of the US images at a later date. This final interpretation was blinded to both clinical and radiography outcomes. The reference standard was an attending radiologist's interpretation of radiographs. The primary outcome was the accuracy of the blinded US interpretation for detecting clavicle fractures compared to the reference standard. Secondary outcome measures included the interrater reliability of the unblinded bedside and the blinded physicians' interpretations and the FACES pain scores (range, 0-5) for US and radiograph imaging. RESULTS: One-hundred patients were included in the study, of whom 43 had clavicle fractures by radiography. The final US interpretation had 95% sensitivity (95% confidence interval [CI] = 83% to 99%) and 96% specificity (95% CI = 87% to 99%), and overall accuracy was 96%, with 96 congruent readings. Positive and negative predictive values (PPVs and NPVs, respectively) were 95% (95% CI = 83% to 99%) and 96% (95% CI = 87% to 99%), respectively. Interrater reliability (kappa) was 0.74 (95% CI = 0.60 to 0.88). FACES pain scores were available for the 86 subjects who were at least 5 years old. Pain scores were similar during US and radiography. CONCLUSIONS: Compared to radiographs, bedside US can accurately diagnose pediatric clavicle fractures. US causes no more discomfort than radiography when detecting clavicle fractures. Given US's advantage of no radiation, pediatric EPs should consider this application.
31
Lawrence A. Melniker, Evan Leibner, Mark McKenney et al. · Annals of Emergency Medicine · 2006 · 408 citations
Medicine, Emergency Medical Services, Emergency Medicine +11
Interobserver Reliability of the Chest Radiograph in Community-Acquired Pneumonia
Michael N. Albaum, Lisa C. Hill, Miles Murphy et al. · CHEST Journal · 1996 · 282 citations
The aetiology and epidemiology of clavicular fractures
Jan Krzysztof Nowak, Hans Mallmin, Sune Larsson · Injury · 2000 · 258 citations