Journal of neurosurgery · 2009 · 141 citations · 19 references
MedicineAnesthesiologyOphthalmologyAnesthesiaOphthalmic SurgeryVisual ElectrophysiologyAnesthesia For Ophthalmic SurgeryEvoked PotentialsIntraoperative Neurophysiological MonitoringVisual Evoked PotentialsElectroretinographyEvoked Potential MonitoringPostoperative Visual LossRed Light-emitting DiodesRetinal Light StimulationRetinal StimulationVisual Function MeasurementVisually Evoked Potentials
OBJECT: To obtain a clinically useful method of intraoperative monitoring of visual evoked potentials (VEPs), the authors developed a new light-stimulating device and introduced electroretinography (ERG) to ascertain retinal light stimulation after induction of venous anesthesia. METHODS: The new stimulating device consists of 16 red light-emitting diodes embedded in a soft silicone disc to avoid deviation of the light axis after frontal scalp-flap reflection. After induction of venous anesthesia with propofol, the authors performed ERG and VEP recording in 100 patients (200 eyes) who were at intraoperative risk for visual impairment. RESULTS: Stable ERG and VEP recordings were obtained in 187 eyes. In 12 eyes, stable ERG data were recorded but VEPs could not be obtained, probably because all 12 eyes manifested severe preoperative visual dysfunction. The disappearance of ERG data and VEPs in the 13th eye after frontal scalp-flap reflection suggested technical failure attributable to deviation of the light axis. The criterion for amplitude changes was defined as a 50% increase or decrease in amplitude compared with the control level. In 1 of 187 eyes the authors observed an increase in intraoperative amplitude and postoperative visual function improvement. Of 169 eyes without amplitude changes, 17 manifested improved visual function postoperatively, 150 showed no change, and 2 worsened (1 patient with a temporal tumor developed a slight visual field defect in both eyes). Of 3 eyes with intraoperative VEP deterioration and subsequent recovery upon changing the operative maneuver, 1 improved and 2 exhibited no change. The VEP amplitude decreased without subsequent recovery to 50% of the control level in 14 eyes, and all of these developed various degrees of postoperative deterioration of visual function. CONCLUSIONS: With the strategy introduced here it is possible to record intraoperative VEPs in almost all patients except in those with severe visual dysfunction. In some patients, postoperative visual deterioration can be avoided or minimized by intraoperative VEP recording. All patients without an intraoperative decrease in the VEP amplitude were without severe postoperative deterioration in visual function, suggesting that intraoperative VEP monitoring may contribute to prevent postoperative visual dysfunction.
19
Aneurysms of the ophthalmic segment
Arthur L. Day · Journal of neurosurgery · 1990 · 414 citations
Medicine, Neurosurgery, Surgery +10
INTRAOPERATIVE MONITORING OF EVOKED POTENTIALS
Peter A. Raudzens · Annals of the New York Academy of Sciences · 1982 · 177 citations
Medicine, Neuroscience, Surgery +12
Monitoring optic nerve function during craniotomy
Moshé Feinsod, John B. Selhorst, William F. Hoyt et al. · Journal of neurosurgery · 1976 · 97 citations