Nuclear safety · 1996 · 41 citations · 0 references
EngineeringNuclear EngineeringNuclear MaterialsNuclear Safety AnalysisSafety EngineeringChemical Reactivity HazardsReactivity Accident AnalysisSevere Accident AnalysisBoiling Water ReactorsCladding FailureCladding Failure MechanismsFission Product ReleasePressurized Water ReactorsReactivityReactor Safety AnalysisSafety Analysis
An assessment is made of recent test data from France, Japan, and Russia and of earlier test data from the United States in relation to the safety analysis performed for reactivity-initiated accidents in power reactors in the United States. Considerations include mode of cladding failure, oxidation, hydriding, and pulse-width effects. From the data trend and from these considerations, we conclude that the cladding failure threshold for fuel rods with moderate-to-high burnup is roughly 100-cal/g fuel peak fuel-rod enthalpy for boiling-water reactors and pressurized-water reactors. Realistic plant calculations suggest that cladding failure would not occur for rod-ejection or rod-drop accidents and therefore that pellet fragmentation and enhanced fission-product release from fuel pellets should not have to be considered in the safety analysis for these reactivity accidents. The data base, however, is sparse and contains much uncertainty. 32 refs., 11 figs., 8 tabs.