International Conference on Electrical Machines and Systems · 2012 · 13 citations · 2 references
EngineeringElectrical EngineeringElectric MachinesElectromagneticsPower ElectronicsBrushless Dc MachinesDirect Current MachinesElectric DrivesElectric MotorsLosses In Electric MachinesPermanent Magnet MachinesCore LossesElectric Motor ControlFlux ControlFlux Weakening ControlMotor LossesPermanent Magnet MotorsVariable-speed MotorsVoltage
The motors used in electrical vehicles and electrical appliances operate at variable speeds using flux-weakening control. The flux-weakening current, which depresses the voltage at high speeds, causes significant copper and core losses. Therefore, we developed a new technique for changing the number of poles and the machine constants in a permanent magnet motor on the basis of its speed. In this paper, we propose a novel motor capable of changing the number of poles and the machine constants and clarify its principle and basic characteristics. The results show that the permanent magnet motor can vary the motor's induced voltage can be varied from 24% to 100% by pole-changing.
2
Principle of the variable-magnetic-force memory motor
Kazuto Sakai, Kazuaki Yuki, Yutaka Hashiba et al. · 2009 · 188 citations
Engineering, Automotive Engineering, Electrical Engineering +17