Dynamic Particulate Measurements from a DISI Vehicle: A Comparison of DMS500, ELPI, CPC and PASS

Philip Price, Richard Stone, Tony Collier, Marcus Davies, Volker Scheer

SAE technical papers on CD-ROM/SAE technical paper series · 2006 · 38 citations · 16 references

Concepts

Abstract

<div class="htmlview paragraph">A Cambustion Differential Mobility Spectrometer (DMS500), Dekati Electrical Low Pressure Impactor (ELPI), TSI Condensation Particle Counter (CPC) and AVL Photo-Acoustic Soot Sensor (PASS) were compared for measurements of emitted Particulate Matter (PM) from a Direct Injection Spark Ignition (DISI) vehicle on the New European Drive Cycle (NEDC) and at steady speed operating points. The exhaust was diluted in a Constant Volume Sampler (CVS) before being measured.</div> <div class="htmlview paragraph">Transient size spectral data from the DMS500 and ELPI is presented. PM Number rate and total PM number emissions are presented for the DMS500, ELPI and CPC. The DMS500 and ELPI data are post-processed for PM mass, and presented with data from the PASS. The instrument responses were correlated against each other.</div> <div class="htmlview paragraph">Qualitative agreement was generally found between all instruments. The agreement was closer for PM mass measurements than for measurements of PM number. The correlations were slightly weaker for the DISI exhaust measured here than for measurements of diesel exhaust in the literature.</div>

References

16