Residential vertical geothermal heat pump system models: calibration to data

Jeff Thornton, Timothy P. McDowell, John A Shonder, Patrick Hughes, Daniel Pahud, Göran Hellström

SUPSI ARIS · 1997 · 52 citations · 1 references

DOIFull text

Open access

Concepts

Abstract

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower and ground loop pump. Each of these component models were "tuned" to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.

References

1