Journal of Applied Physics · 2015 · 54 citations · 16 references
Natural SciencesMaterials EngineeringMaterials ScienceHeat TransferMagnetic MaterialsThermodynamicsCurie TemperatureHeat Transfer ModelingMagnetocaloric MaterialsRefrigerationRefrigeration SystemsThermal ManagementCurie Temperature DeterminationCurie Temperature PredictionEntropy ChangeMagnetic Entropy ChangeMagnetic RefrigerationMagnetic Refrigeration MaterialsMagnetic Specific HeatSensitivity
We present simulation results of multi-layer active magnetic regenerators using the solid-state refrigerant La(Fe,Mn,Si) 13 H y . This material presents a large, however quite sharp, isothermal entropy change that requires a careful choice of number of layers and working temperature for multi-layer regenerators. The impact of the number of layers and the sensitivity to the working temperature as well as the temperature span are quantified using a one dimensional numerical model. A study of the sensitivity of variation in Curie temperature through a uniform and normal distribution is also presented. The results show that the nominal cooling power is very sensitive to the Curie temperature variation in the multi-layer regenerators. A standard deviation of the Curie temperature variation for a normal distribution less than 0.6 K is suggested in order to achieve sufficient performance of a 15layer regenerator with Curie temperature spacing of 2 K.
16