Journal of Biomedical Materials Research Part B Applied Biomaterials · 2014 · 27 citations · 36 references
Natural SciencesMaterials EngineeringMaterials ScienceCorrosion ScienceSurface EngineeringSurface ScienceCoatingsCorrosion EngineeringCorrosion ResistanceCorrosion-resistant MaterialsPlasma-surface InteractionsSurface CoatingsCorrosion PotentialCorrosion Resistance ImprovementCorrosion-resistance MechanismsHydrophilic CoatingsNanocoatingsPlasma TreatmentPlasma-deposited NanocoatingsSurface Properties
To improve their corrosion resistance and thus long-term biocompatibility, 316L stainless steel coronary artery stents were coated with trimethylsilane (TMS) plasma coatings of 20-25 nm in thickness. Both direct current (DC) and radio-frequency (RF) glow discharges were utilized for TMS plasma coatings and additional NH₃/O₂ plasma treatment to tailor the surface properties. X-ray photoelectron spectroscopy (XPS) was used to characterize the coating surface chemistry. It was found that both DC and RF TMS plasma coatings had Si- and C-rich composition, and the O- and N-contents on the surfaces were substantially increased after NH₃/O₂ plasma treatment. Surface contact angle measurements showed that DC TMS plasma nanocoating with NH₃/O₂ plasma treatment generated very hydrophilic surface. The corrosion resistance of TMS plasma coated stents was evaluated through potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques. The potentiodynamic polarization demonstrated that the TMS plasma coated stents imparted higher corrosion potential and pitting potential, as well as lower corrosion current densities as compared with uncoated controls. The surface morphology of stents before and after potentiodynamic polarization testing was analyzed with scanning electron microscopy, which indicated less corrosion on coated stents than uncoated controls. It was also noted that, from EIS data, the hydrophobic TMS plasma nanocoatings showed stable impedance modulus at 0.1 Hz after 21 day immersion in an electrolyte solution. These results suggest improved corrosion resistance of the 316L stainless steel stents by TMS plasma nanocoatings and great promise in reducing and blocking metallic ions releasing into the bloodstream.
36
Clinical experience with the Palmaz-Schatz coronary stent. Initial results of a multicenter study.
Richard A. Schatz, Donald S. Baim, M.B. Leon et al. · Circulation · 1991 · 608 citations · Full text
Medicine, Cardiology, Surgery +17
Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
Ralf Köster, Dieter Vieluf, Margret Kiehn et al. · The Lancet · 2000 · 530 citations
Medicine, Cardiology, Immunology +14
Intracoronary ultrasound observations during stent implantation.
Shigeru Nakamura, Antonio Colombo, Antonio Gaglione et al. · Circulation · 1994 · 395 citations · Full text
Medicine, Cardiology, Radiology +14