Pediatric Diabetes · 2014 · 11 citations · 24 references
MedicineEndocrinologyPediatricsClinical CardiologyDiabetologyPediatric CardiologyCardiovascular AssessmentCardiovascular DiseaseDiabetes MellitusDoppler UltrasoundHypertension In ChildrenPediatric EchocardiographyB-type Natriuretic PeptidesBlood PressureBlood Pressure MeasurementBlood Pressure MonitoringDiastolic Blood Pressure EstimationDiastolic Function EvaluationPediatric Blood Pressure MeasurementSpectral Doppler Ultrasonography
AIM: To evaluate the relationship between 24-h blood pressure (BP) measurements and diastolic heart function evaluated by Doppler tissue imaging and B-type natriuretic peptide (BNP) levels in children with type 1 diabetes mellitus (DM). PATIENTS AND METHODS: A total of 32 diabetic and 18 healthy children were enrolled. Spectral Doppler analysis and tissue Doppler measurements were performed by conventional echocardiography. The 24-h ambulatory BP and serum BNP levels were measured. RESULTS: Analysis of ambulatory blood pressure monitoring (ABPM) recordings showed that median daytime diastolic BP load were significantly higher in diabetic patients compared to controls [12.35 (4.23-27.23) vs. 2.5 (0-8.7), p = 0.007]. Patients with elevated daytime systolic and diastolic BP loads had significantly higher BNP values compared to patients with normal BP load (31.4 ± 24.36 vs. 11.84 ± 11.25 pg/mL, p = 0.03 and 23.21 ± 15.12 vs. 12.12 ± 14.65 pg/mL, p = 0.03, respectively). Isovolemic contraction time (47.43 ± 7.84 vs. 42.27 ± 7.47, p = 0.045), isovolemic relaxation time (68.84 ± 10.43 vs. 58.77 ± 10.02, p = 0.02), and myocardial performance index (0.45 ± 0.10 vs. 0.37 ± 0.09, p = 0.02) as determined by tissue Doppler echocardiography were significantly high in diabetic patients compared to that of control cases. Ratio of mitral peak early diastolic flow velocity (E) to peak early diastolic myocardial velocities by tissue Doppler echocardiography (E') was also higher in patients with elevated daytime systolic BP load (E/E', 6.71 ± 1.97 vs. 4.91 ± 1.02, p = 0.04). CONCLUSION: Elevated BP loads detected by 24-h ambulatory BP measurements in children with type 1 diabetes are associated with increased BNP levels and abnormal tissue Doppler echocardiography indices, indicating early stage cardiac dysfunction.
24
Validation of the mobil-O-Graph: 24 h-blood pressure measurement device
Wolfgang Wei, Markus Tölle, Walter Zidek et al. · Blood Pressure Monitoring · 2010 · 261 citations
Microvascular and macrovascular complications in children and adolescents
Kim C. Donaghue, R. Paul Wadwa, Linda A. DiMeglio et al. · Pediatric Diabetes · 2014 · 180 citations
Medicine, Child Health, Pediatrics +12