Nuclear Science and Engineering · 1990 · 20 citations · 4 references
EngineeringNuclear EngineeringPhysicsAnalog ElectronicsNuclear PhysicsReactor PhysicsNeutron DetectionNuclear DecayRadioactive DecayReactor DynamicsReactor InstrumentationReactor KineticsCompensating PolesCompensation TechniquesDynamic CompensationInverse Kinetics ModelingLead-lag RelationsLead-lag RelationshipsPolesSelf-powered Neutron Detectors
Analog and digital methods have been developed to compensate for the time delay associated with rhodium self-powered neutron detector signals. This delay is caused by the decay of the neutron-activated rhodium and results in a current signal with unfavorable time response characteristics. The compensating analog method is based on the use of lead-lag networks to eliminate undesirable poles and zeros. The digital method takes digitized signals and numerically solves the inverse kinetics equation that relates reactor flux to the detector current at all earlier times. These methods were tested in a realistic reactor environment, and the results illustrate the accuracy achieved using each method.
4