Cost-effectiveness analysis: comparing single-level cervical disc replacement and single-level anterior cervical discectomy and fusion

83

Citations

35

References

2013

Year

Abstract

Both CDR and ACDF were shown to be cost-effective procedures in the reference case. Results of the sensitivity analysis indicated that CDR must remain functional for at least 14 years to establish greater cost-effectiveness than ACDF. Since the current literature has yet to demonstrate with certainty the actual durability and long-term functionality of CDR, future long-term studies are required to validate the present analysis.