The Laryngoscope · 2014 · 20 citations · 23 references
MedicineClinical SciencesOtolaryngologyLaryngologyOtolaryngologic SurgeryPulmonologyAirway AssessmentAirway DisordersAirway ImagingAirway ObstructionLaryngeal ImagingNeck AssessmentMallampati ClassificationPilot DesignPilot Study DesignPilot Study PlanningPilot Study Sample SizePositive Predictive ValuePositive Predictive Value EstimationPredictors Of Surgical Success
OBJECTIVES/HYPOTHESIS: To determine whether Mallampati class correlates with Cormack-Lehane grade in obese adults, and investigate a novel airway trajectory measurement (ATM) to anticipate difficult laryngoscopy. STUDY DESIGN: Retrospective cohort plus a pilot study. METHODS: One hundred eighty-four nonobese and 160 obese adults underwent laryngoscopy. Spearman correlations, gamma coefficients (G), and Kendall's τ investigated body mass index (BMI):Mallampati, BMI: Cormack-Lehane, and Mallampati:Cormack-Lehane. A z test compared the two groups. Twenty-six volunteers had neck x-rays taken in the sniffing position to examine trajectories to the larynges (ATM). RESULTS: Positive predictive value of high Mallampati for difficult laryngoscopy was 8.57%. BMI did not correlate with Mallampati (r = 0.055 [nonobese], r = -0.056 [obese]) or Cormack-Lehane [r = -0.014 [nonobese], r = -0.022 [obese]). Among nonobese adults, gamma coefficients for BMI:Mallampati was 0.039 (P = .63), for BMI:Cormack-Lehane was 0.02 (P = .85), and for Mallampati:Cormack-Lehane was 0.43 (P = .004). Among obese adults, gamma coefficients for BMI:Mallampati was -0.127 (P = .16), for BMI:Cormack-Lehane was 0.014 (P = .88), and for Mallampati:Cormack-Lehane was 0.365 (P = .01). Kendall's τ were comparable to gamma coefficients in all analyses. When comparing gamma coefficients for Mallampati:Cormack-Lehane among the nonobese and obese, z = 0.04 (P = .98). In the ATM study, only Mallampati and upper lip bite test had a significant relationship (G = 1.00, P < .001). CONCLUSIONS: Mallampati correlates poorly with Cormack-Lehane, regardless of BMI. Pilot data suggest that ATM is feasible.
23
Difficult tracheal intubation in obstetrics
R. S. Cormack, J. R. Lehane · Anaesthesia · 1984 · 2.5K citations
Medicine, Anesthesiology, Obstetrics +10
Difficult tracheal intubation: a retrospective study
G. Samsoon, J. R. B. Young · Anaesthesia · 1987 · 1.6K citations · Full text
Medicine, Anesthesiology, Surgery +14
The Intubation Difficulty Scale (IDS)
Frédéric Adnet, Stephen W. Borron, S.X. Racine et al. · Anesthesiology · 1997 · 709 citations · Full text
Difficult Tracheal Intubation Is More Common in Obese Than in Lean Patients
Philippe Juvin, Elisabeth Lavaut, Hervé Dupont et al. · Anesthesia & Analgesia · 2003 · 528 citations
Medicine, Anesthesiology, Physiology +14