Applied Physics Letters · 2015 · 34 citations · 12 references
EngineeringMechanical EngineeringPhysicsActuatorsHeat TransferPlasma PhysicsHigh-temperature PlasmasLow-temperature PlasmasThermal ActuatorsChannel ConfigurationConvective Heat TransferEnergy Conversion EfficiencyFlow Rate ControlPlasma Jet FormationSignal ManipulationSurface CoolingSurface Cooling Effects
We introduce a milliwatt class needle actuator suitable for plasma channels, vortex generation, and surface cooling. Electrode configurations tested for a channel configuration show 1400% and 300% increase in energy conversion efficiency as compared to conventional surface and channel corona actuators, respectively, generating up to 3.4 m/s air jet across the channel outlet. The positive polarity of the needle is shown to have a beneficial effect on actuator efficiency. Needle-plate configuration is demonstrated for improving cooling of a flat surface with a 57% increase in convective heat transfer coefficient. Vortex generation by selective input signal manipulation is also demonstrated.
12
Airflow control by non-thermal plasma actuators
Éric Moreau · Journal of Physics D Applied Physics · 2007 · 1.6K citations