Anaesthesia · 1981 · 54 citations · 5 references
Veterinary MedicineOperative DentistryAir PollutionAnesthesiaDental AnesthesiaAnesthesia For Dental ProceduresNitrogen OxidesNitrous OxideNitrous Oxide ConcentrationOutpatient Dental Anesthesia
Pollution in the dental outpatients surgery was assessed by measuring atmospheric nitrous oxide levels and comparing these with the venous blood concentrations in the operator-anaesthetist and his assistant. The effects of scavenging on both measurements have also been determined. Without scavenging the nitrous oxide level in the blood of the dentist was over four times that of the average anaesthetist working in an operating theatre. Some of the factors contributing to these high levels, and the effectiveness of scavenging are discussed.
5
Estimation of nitrous oxide in blood
Yussuf Saloojee, Peter Cole · Anaesthesia · 1978 · 11 citations · Full text