Journal of Clinical Microbiology · 1987 · 27 citations · 3 references
PharmacyToxicologyAnalytical ChemistryAnalytical ToxicologyGood Laboratory PracticeAcid-base ManagementInstrumental AnalysisDisposalMaterial Recovery Rates
In comparative studies, Hemo-De (PMP Medical Industries, Inc., Irving, Tex.) was found to be a suitable replacement for ethyl acetate in the Formalin-ethyl acetate concentration technique. With essentially equivalent recovery rates for both procedures, the Formalin-Hemo-De concentration technique is considered to be the preferred technique because Hemo-De is less toxic and less flammable and does not present disposal problems, and its cost is approximately one-fourth that of ethyl acetate.
3
An ether sedimentation technique for routine stool examinations.
Ritchie Ls · PubMed · 1947 · 561 citations