Radio Science · 1979 · 31 citations · 3 references
MedicineBiophysicsPhysiologyAntennasMedical PhysicsRadiation DosimetryAbsorbed DoseBiological Effects Of RadiationRadiobiological ConsiderationsRadiobiological ModelingAntenna TheoryBarbiturate AnesthesiaEmpirical Prediction EquationsEnergy DepositionMultibody System ModelingRadiation Dose AssessmentResonanceWhole-body Physiology
Fine structure in the whole-body resonant curve for radio-frequency energy deposition in man can be attributed to part-body resonances. As for head resonance, which occurs near 350 MHz in man, the absorptive cross section is nearly three times the physical cross section of the head. The arm has a prominent resonance at 150 MHz. Numerical solutions, antenna theory, and experimental results on animals have shown that whole-body energy deposition may be increased by 50 percent or more because of multiple bodies that are strategically located in the field. Empirical equations for SARs are also presented along with test data for several species of laboratory animals. Barbiturate anesthesia is sufficiently disruptive of thermoregulation that delta Ts of colonic temperature yield energy dose values in several mammals that compare quite favorably with those based on whole-body calorimetry.
3
Drug‐induced ectothermia in small mammals: The quest for a biological microwave dosimeter
D. L. Putthoff, Don R. Justesen, L Ward et al. · Radio Science · 1977 · 15 citations