BJOG An International Journal of Obstetrics & Gynaecology · 2009 · 64 citations · 30 references
Life SciencesObstetricsPhysiologyBiomedical Signal ProcessingDevelopmental PhysiologyMaternal-fetal MedicineFetal DistressFetal MonitoringHeart Rate VariabilityLabor PhysiologyMaternal-fetal PhysiologyPregnancy PhysiologyAutonomic Nervous System ChangesFetal Electrocardiogram AnalysisFetal Heart Rate VariabilityFetal Heart Rate Variability AnalysisFetal Physiological MonitoringHeart Rate Variability IndicesHeart Rate Variability MeasurementShort-time Fourier Transform
OBJECTIVE: Spectral analysis of heart-rate variability is used to monitor autonomic nervous system fluctuations. The low-frequency component is associated with sympathetic and parasympathetic modulation and the high-frequency component is associated with parasympathetic modulation. The objective was to study whether changes in low-frequency or high-frequency power of heart-rate variability occur in case of fetal distress. DESIGN: Case-control study. SETTING: Obstetric unit of a tertiary-care teaching hospital. POPULATION: Twenty healthy human fetuses during labour at term of which ten had an umbilical artery pH < 7.05 (cases), and ten had an arterial pH > 7.20 (controls) after birth. METHODS: Spectral information about fetal beat-to-beat heart rate, calculated from direct fetal electrocardiogram registrations, was obtained by using a short-time Fourier transform. MAIN OUTCOME MEASURES: Absolute power and normalised power in the low-frequency and high-frequency bands. RESULTS: No differences were found between fetuses with and without acidaemia in absolute low or high frequency power (P = 0.2 and P = 0.3, respectively). During the last 30 minutes of labour, acidaemic fetuses had significantly increased normalised low-frequency power (P = 0.01) and decreased normalised high-frequency power (P = 0.03) compared with non-acidaemic fetuses. These differences were not observed from 3 to 2 hours before birth (P = 0.7 and P = 0.9, respectively). CONCLUSION: The autonomic nervous system of human fetuses at term responds adequately to severe stress during labour. Normalised low and high frequency power of heart-rate variability might be able to discriminate between normal and abnormal fetal condition.
30
Task Force of the European Society of Cardiology the North A Electrophysiology · Circulation · 1996 · 16.9K citations
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Marek Malik, J. Thomas Bigger, A. John Camm et al. · European Heart Journal · 1996 · 15.3K citations · Full text
Nursing, Cardiology, Physiology +15
Kenneth G. Goldaber, Larry C. Gilstrap, Kenneth J. Leveno et al. · American Journal of Obstetrics and Gynecology · 1991 · 341 citations