Rapid Communications in Mass Spectrometry · 2011 · 15 citations · 37 references
Natural SciencesChemistryMaterials ScienceAnalytical ChemistryMass Spectrometric AnalysisPolymer ChemistryIonization TechniquesMass AnalyzersMass SpectrometryPolymer AnalysisCarbon DepositionMass Spectral FragmentationPolyethylene TerephthalatePolymer Mass SpectrometryQuadrupole Mass AnalyzersQuadrupole Mass SpectrometrySecondary Ion Mass SpectrometrySputtering
Dynamic secondary ion mass spectrometry (D-SIMS) analysis of poly(ethylene terephthalate) (PET) and poly(methyl methacrylate) (PMMA) was conducted using a quadrupole mass analyzer with various combinations of continuous C(60)(+) and Ar(+) ion sputtering. Individually, the Ar(+) beam failed to generate fragments above m/z 200, and the C(60)(+) beam generated molecular fragments of m/z ~1000. By combining the two beams, the auxiliary Ar(+) beam, which is proposed to suppress carbon deposition due to C(60)(+) bombardment and/or remove graphitized polymer, the sputtering range of the C(60)(+) beam is extended. Another advantage of this technique is that the high sputtering rate and associated high molecular ion intensity of the C(60)(+) beam generate adequate high-mass fragments that mask the damage from the Ar(+) beam. As a result, fragments at m/z ~900 can be clearly observed. As a depth-profiling tool, the single C(60)(+) beam cannot reach a steady state for either PET or PMMA at high ion fluence, and the intensity of the molecular fragments produced by the beam decreases with increasing C(60)(+) fluence. As a result, the single C(60)(+) beam is suitable for profiling surface layers with limited thickness. With C(60)(+)-Ar(+) co-sputtering, although the initial drop in intensity is more significant than with single C(60)(+) ionization because of the damage introduced by the auxiliary Ar(+), the intensity levels indicate that a more steady-state process can be achieved. In addition, the secondary ion intensity at high fluence is higher with co-sputtering. As a result, the sputtered depth is enhanced with co-sputtering and the technique is suitable for profiling thick layers. Furthermore, co-sputtering yields a smoother surface than single C(60)(+) sputtering.
37
Daniel E. Weibel, Steve Wong, Nicholas P. Lockyer et al. · Analytical Chemistry · 2003 · 539 citations
Cluster primary ion bombardment of organic materials
Felix Kollmer · Applied Surface Science · 2004 · 285 citations
Cluster primary ion bombardment of organic materials
Felix Kollmer · Applied Surface Science · 2004 · 227 citations
Impact of slow gold clusters on various solids: nonlinear effects in secondary ion emission
M. Benguerba, Alain Brunelle, S. Della‐Negra et al. · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · 1991 · 183 citations
Natural Sciences, Chemistry, Physics +17