Clinical Implant Dentistry and Related Research · 2011 · 80 citations · 23 references
DentistryImplant DentistryMaxillofacial SurgeryBone AugmentationDentoalveolar SurgeryImplant SurgeryImplant DesignImplant Site AssessmentImplant Site PreparationPrimary StabilityDental ImplantsImplant MacrodesignImplant StabilityPrimary Stability DesignPrimary Stability PredictionResonance AnalysisSelf-tapping ImplantsSurgical Implant Placement
PURPOSE: The aim of this study was to investigate the relationship between surgical techniques and implant macro-design (self-tapping/non-self-tapping) for the optimization of implant stability in the low-density bone present in the posterior maxilla using resonance frequency analysis (RFA). MATERIALS AND METHODS: A total of 102 implants were studied. Fifty-six self-tapping BlueSkyBredent® (Bredent GmbH&Co.Kg®, Senden, Germany) and 56 non-self-tapping Standard Plus Straumann® (Institut Straumann AG®, Waldenburg, Switzerland) were placed in the posterior segment of the maxilla. Implants of both types were placed in sites prepared with either lateral bone-condensing or with bone-drilling techniques. Implant stability measurements were performed using RFA immediately after implant placement and weekly during a 12-week follow-up period. RESULTS: Both types of implants placed after bone condensing achieved significantly higher stability immediately after surgery, as well as during the entire 12-week observation period compared with those placed following bone drilling. After bone condensation, there were no significant differences in primary stability or in implant stability after the first week between both implant types. From 2 to 12 postoperative weeks, significantly higher stability was shown by self-tapping implants. After bone drilling, self-tapping implants achieved significantly higher stability than non-self-tapping implants during the entire follow-up period. CONCLUSIONS: The outcomes of the present study indicate that bone drilling is not an effective technique for improving implant stability and, following this technique, the use of self-tapping implants is highly recommended. Implant stability optimization in the soft bone can be achieved by lateral bone-condensing technique, regardless of implant macro-design.
23
Assessment of implant stability as a prognostic determinant.
Neil Meredith · PubMed · 1999 · 822 citations
De novo alveolar bone formation adjacent to endosseous implants
Tord Berglundh, Ingemar Abrahamsson, Niklaus P. Lang et al. · Clinical Oral Implants Research · 2003 · 687 citations · Full text
Medicine, Surgery, Bone Grafting +13
The regional acceleratory phenomenon: a review.
Harold M. Frost · PubMed · 1983 · 674 citations