IET Power Electronics · 2012 · 42 citations · 23 references
EngineeringElectrical EngineeringLow-power DesignPower ElectronicsRenewable Energy SystemsAc-dc ConversionAc-dc ConvertersDc-dc ConversionDc-dc ConvertersPower Factor CorrectionPower QualityBoost Power Factor Correction ConvertersContinuous Conduction Mode OperationCurrent Control Of Power ConvertersDigital Control Of Power ConvertersLoad Variation CompensationPower FactorPower Factor ControlPower Output
This study proposes two digital predictive current controllers applied to the boost power factor correction (PFC) converter able to operate with a load variation up to 600 W. A comparison between them is made to determine which controller presents the best performance and benefit–cost ratio. They have in common the possibility of operation in discontinuous, mixed and continuous conduction modes. This operation capability yields several advantages to boost PFC converters with variable loads, as will be discussed. The control laws and the structure of the proposed controllers are shown in detail. Implementation issues (hardware and software) are also shown. Experimental results point out that high converter power factor and low input current total harmonic distortion (THD) are achieved over the entire output power range using both current controllers, with a low implementation cost.
23
K. DeGusseme, D.M. VandeSype, A.P.M. VandenBossche et al. · IEEE Transactions on Industrial Electronics · 2005 · 183 citations
J. Sebastián, J.A. Cobos, J.M. Lopera et al. · IEEE Transactions on Power Electronics · 1995 · 141 citations · Full text