Anaesthesia · 2011 · 30 citations · 17 references
MedicineAnesthesiologyAnesthesiaGeneral AnesthesiaLaryngologyCardiovascular MonitoringHemodynamic Response To AnesthesiaBlood PressureHeart RateHemodynamic Effects Of AnesthesiaHemodynamic Response To IntubationSystolic Blood PressureTracheal Intubation Effects
We compared the effects of the Airway Scope(®) on haemodynamic responses during tracheal intubation with those of direct laryngoscopy in normotensive and hypertensive patients. The systolic blood pressure, diastolic blood pressures and heart rate were recorded: (a) before anaesthesia; (b) immediately before intubation; (c) at intubation; and (d) 1, 2, 3, 4 and 5 min after intubation. In normotensive patients, the increase in blood pressure and heart rate over time were significantly lower with the Airway Scope than with the Macintosh laryngoscope (p < 0.003). In hypertensive patients, however, there was no difference in the changes over time in any of these haemodynamic measures between the two devices (p > 0.05). We conclude that the Airway Scope attenuates haemodynamic responses to tracheal intubation in comparison with the laryngoscope in normotensive but not in hypertensive patients. You can respond to this article at http://www.anaesthesiacorrespondence.com.
17
Complications Related to the Pressor Response to Endotracheal Intubation
Elisabeth Fox, Garry S. Sklar, Constance H. Hill et al. · Anesthesiology · 1977 · 376 citations · Full text