EPJ Web of Conferences · 2015 · 11 citations · 0 references
EngineeringNuclear EngineeringInstrumentationMaterials CharacterizationNuclear InstrumentationFlow MeasurementMoisture DeterminationData ProcessingLiquid DistributionLow-pressure MeasurementSteam Power SystemsSteam TurbinesTurbine PerformanceTurbine TechnologyTurbines
The aim of this paper is to introduce the measurement capacity of a new generation of CTU’s optical probes to determine the liquid phase distribution in steam turbines and other energy systems. At the same time the paper presents the first part of the results concerning output wetness achieved through the use of experimental research performed with the probes in a new low pressure (LP) part of the steam turbine 1000MW in the Temelin nuclear power plant (ETE). Two different probes were used. A small size extinction probe with a diameter of 25mm which was developed for measuring in a wider range of turbines in comparison with the previous generation with a diameter of 50mm. The second probe used was a photogrammetric probe developed to observe the coarse droplets. This probe is still under development and this measurement was focused on verifying the capabilities of the probe. The data processing technique is presented together with yielded examples of the wetness distribution along the last blade of the 1000MW steam turbine. The experimental measurement was done in cooperation with Doosan Škoda Power s.r.o. (DSP).