PubMed · 2013 · 10 citations · 19 references
DentistryImplant DentistryOral RadiologyDental RadiologyMaxillofacial ImagingOral AnatomyCone Beam Computed Tomography InterpretationCross-sectional Imaging For Implant PlanningDental ImagingImplant Site AssessmentMandibular AnatomyMandibular RadiographyCone Beam Computed Tomography ComparisonCone Beam Computed Tomography LandmarksCone-beam Computed Tomography (Cbct)Mandibular Canal AssessmentMandibular Canal IdentificationMandibular Incisive CanalMulti-slice Computed TomographyThree-dimensional Mandibular Imaging
BACKGROUND: Cross- sectional tomograms have been used for optimal pre-operative planning of dental implant placement. The aim of the present study was to assess the accuracy of Cone Beam Computed Tomography (CBCT) measurements of specific distances around the mandibular canal by comparing them to those obtained from Multi-Slice Computed Tomography (MSCT) images. MATERIALS AND METHODS: Ten hemi-mandible specimens were examined using CBCT and MSCT. Before imaging, wires were placed at 7 locations between the anterior margin of the third molar and the anterior margin of the second premolar as reference points. Following distances were measured by two observers on each cross-sectional CBCT and MSCT image: Mandibular Width (W), Length (L), Upper Distance (UD), Lower Distance (LD), Buccal Distance (BD), and Lingual Distance (LID). The obtained data were evaluated using SPSS software, applying paired t-test and intra-class correlation coefficient (ICC). RESULTS: There was a significant difference between the values obtained by MSCT and CBCT measurement for all areas such as H, W, UD, LD, BD, and LID, (P < 0.001), with a difference less than 1 mm. The ICC for all distances by both techniques, measured by a single observer with a one week interval and between 2 observers was 99% and 98%, respectively. Comparing the obtained data of both techniques indicates that the difference between two techniques is 2.17% relative to MSCT. CONCLUSION: The results of this study showed that there is significant difference between measurements obtained by CBCT and MSCT. However, the difference is not clinically significant.
19
Accuracy in measurement of distance using limited cone-beam computerized tomography.
Kaoru Kobayashi, Shinji Shimoda, Yoichi Nakagawa et al. · PubMed · 2004 · 410 citations
Dentistry, Oral Radiology, Radiology +17
Danielle R. Periago, William C. Scarfe, Mazyar Moshiri et al. · The Angle Orthodontist · 2007 · 320 citations · Full text